General preventive maintenance schedule needs to be followed as instructed in the operation manual. Also in case of universal treater where in ceramic electrodes are used, proper cleaning and maintenance of these electrodes is essential. The electrodes and electrode holding blocks need to be cleaned with Acetone/Iso Propyl Alcohol solutions. Improper maintenance of the ceramic electrode can lead to premature failure or cracks. Also ensure that the Ozone extraction system is properly maintained and a good negative static pressure is maintained in the ducting chamber. Proper cleaning of Treater roller is essential to prevent corrosion or contamination with the external dust or foreign particles.